News

How To Solve The Problem Of Low Water Output After The Industrial Corrosion-resistant Self-priming Pump Is Started

Publish Time: Author: Site Editor Visit: 32

When we are not feeling well, it will affect the progress of work. Although Sanitary Centrifugal Pump is a machine, it is the same as us. If there is a problem, it will also affect its operation and efficiency. Today we will take a look at why the industrial corrosion-resistant self-priming pump has little water output after starting, hoping to help those in need.

1. The water suction pipeline is not tight and air is inhaled, and the water output presents white bubbles
Troubleshooting method: Check the water suction pipeline and plug the leaks
2. The rotation direction of the water pump is wrong
Troubleshooting method: Change the power supply wiring of the motor, swap any two of the three wires and start.
3. The valve opening is not enough
Troubleshooting method: Check the valve switch position, find out the cause and open all the valves.
4. The water pump speed is not enough
Troubleshooting method: Check whether the power supply voltage is too low; the speed regulating pump should increase the speed and increase the water discharge head.
5. The pump head is insufficient
Troubleshooting method: Replace the pump with a higher head
6. Flow meter failure
Troubleshooting method: Recalibrate the flow or repair or replace.
7. The water suction pipe or impeller flow channel is blocked by foreign matter. Troubleshooting method: After eliminating other possible causes, the machine can be shut down and disassembled for inspection.

How To Solve The Problem Of Low Water Output After The Industrial Corrosion-resistant Self-priming Pump Is Started

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.